Custom HV/UHV systems.
Built for your process.
We combine sample handling, vacuum chambers, sample preparation modules and control software into HV/UHV systems designed around your sample preparation, processing and analysis workflow.

Your application defines
the architecture.
Build a coherent path from sample introduction to processing, storage and transfer. Mechanical design, vacuum interfaces and control logic are considered together.
Start with the sample
Define the holder, handling constraints and preparation or analysis steps that the system must support.
Connect the process
Coordinate chambers, transfer mechanisms and instrument interfaces across the required vacuum workflow.
Specify the operation
Define manual functions, automation sequences, monitoring and operating rules for the intended use.
Inside a sample preparation system.
This platform illustrates one system architecture OPKI can build. Its combination of modules is adapted to the sample, process and instrument interfaces of each project.

Motorized sample transfer
Move the sample between preparation, storage and analysis positions.
Three-axis positioning
Position the sample with a motorized manipulator.
Thermal annealing
Integrate controlled sample heating and automated annealing sequences.
Ion bombardment
Integrate an ion gun for surface cleaning and preparation before analysis.
In-vacuum storage
Park samples under vacuum between process steps.
Vacuum transport
Transfer samples to a compatible system using a vacuum suitcase.
Design the sample’s journey.
An illustrative workflow brings the required handling and process steps into a coordinated operating sequence.
Introduce
Load samples through a dedicated introduction interface.
Transfer
Route samples between the selected process positions.
Prepare
Combine the preparation functions required by the application.
Store
Keep samples under vacuum between operations.
Transport
Connect the workflow to another compatible instrument.
Workflow shown as an example. The order, process steps and available functions depend on the selected architecture and integrated devices.
Configure the complete system.
Combine the functions your application needs, from a focused transfer arrangement to a multi-module sample preparation platform.
Sample handling
Transfer rods, positioning and storage configured around your sample format.
Vacuum environment
Chambers, load locks, pumping interfaces and pressure monitoring specified together.
Instrument interfaces
Docking and transfer connections defined for the instruments in your workflow.
Control & automation
OPKI ONE coordinates supported devices, operating rules, recipes and monitoring.
Connect your system
to one control environment.
OPKI ONE brings compatible OPKI and external equipment into a unified interface. Supported existing instruments can be incorporated following a review of each model, communication interface and required function.

Connect sample preparation, deposition and analysis.
Plan the vacuum handling around your experiment: sample introduction, positioning, preparation, storage and transfer to the next instrument.
PVD & vacuum evaporation workflows
For physical vapor deposition (PVD), including thermal evaporation workflows, discuss how sample loading, transfer and positioning fit around your deposition chamber. Source selection, substrate temperature, shielding and vacuum interfaces are reviewed for each project.
UHV sample preparation
Combine compatible preparation functions such as thermal annealing and ion cleaning with controlled sample handling. Connect preparation positions to in-vacuum storage and analysis through an architecture adapted to your samples.
Sample transfer for SEM workflows
Define sample-holder compatibility, travel, alignment and chamber interfaces when connecting preparation equipment to a scanning electron microscope (SEM). For air-sensitive samples, discuss vacuum transfer between compatible instruments.
Deposition sources, process capabilities and instrument compatibility are specified individually. The sample preparation platform shown here is an example configuration.
From your process to an integrated architecture.
Define the workflow
Sample format, preparation steps, vacuum conditions, interfaces and automation scope.
Design the architecture
Select modules and specify their mechanical, vacuum and control interfaces.
Integrate the system
Bring hardware, supported instruments and control functions together.
Validate operation
Review the agreed functions, sample-handling sequences and operating conditions.
Specify the interfaces behind the workflow.
An integrated OPKI vacuum system connects sample handling, the vacuum environment and equipment control. Define these three layers together when specifying a new platform or extending an existing installation.
Vacuum and mechanical interfaces
Identify chamber ports, flange types, pumping connections and bakeout constraints. Required pressure conditions and materials are defined for the complete configuration; an individual UHV-compatible component does not establish the performance of the assembled system.
A continuous sample-transfer path
Match holder geometry, transfer stroke, alignment and clearance from the load lock to preparation and storage positions. For transport between instruments, review docking interfaces and the receiving holder arrangement.
Control for new and existing equipment
List each device model, communication interface, command set and available feedback. OPKI ONE can coordinate supported equipment across the workflow; compatibility and operating sequences are confirmed for the selected configuration.
What does your sample need to do?
Tell us about your process and existing instruments. We will help define the modules, interfaces and control scope for your application.
